The Seimens SR75 From the Siemens Solar Web Site:

The Siemens SR75 solar photovoltaic modules (right) efficiently generate power by converting the energy contained in sunlight directly into electricity. They have no moving parts, operate silently, use no fuel, and produce no waste. Built for long-term dependability, the SR75 has a twenty-five year limited warranty on power output.
Electrical Parameters 1
Maximum power rating
Minimum power rating
Rated current
Rated voltage
Short circuit current
Open circuit voltage
Pmax
Pmin
Imp
Vmp
Isc
Voc
Thermal Parameters
Nominal operating cell temperature2
Change of Isc with temperature,
Change of Voc with temperature,
Qualification Test Parameters3
Temperature cycling range
Humidity, freeze, damp heat condition
Maximum system voltage
Wind loading or surface pressure
Maximum distortion4
Hailstone impact withstand
(diameter @ velocity)
Physical Parameters
Number of series cells
Length
Width
Depth
Weight
Warranty5
Power >= 90% of minimum power
Power >= 80% of minimum power
 
[Watts]
[Watts]
[Amps]
[Volts]
[Amps]
[Volts]
 
[°C]
 
 
 
[°C]
[% RH]
[Volts]
[N/m²] (PSF)
[degrees]
[mm @ m/s]
(in @ MPH)
 
 
[mm] (in)
[mm] (in)
[mm] (in)
[kg] (lbs)
 
[Years]
[Years]
SR75
12V
6V*
75
70
4.4
17.0
4.8
21.7
8.8
8.5
9.6
10.9
 
45
+2.06mA/°C (+0.04%/°K)
-0.077 Volts/°C (-0.34%/°K)
 
-40 to +85
85
1000 per ISPRA (EC) [pending],
600 per UL 1703
2400 (50)
1.2
25 @ 23
(1.0 @ 52)
 
36
1200 (47.3)
527 (20.8)
34 (1.3)
7.6 (7.6)
 
10
25
* If the designer chooses to use the 6-volt version in a high voltage array configuration, the designer must install custom large bypass diodes and heat sinks around every 6-volt parallel string.
1 Determined under standard test conditions (STC): Irradiance = 1000w/m² cell temperature = 25 °C; solar spectral irradiance per ASTM E892 (Air Mass = 1.5).
2 Determined under nominal operating conditions (NOC): Irradiance = 800 w/m² ambient temperature = 20 °C; wind speed = 1m/s.
3 Qualification Tests performed as per CEC 503 Test Specification, to ensure durability and performance in outdoor conditions.
4 Diagonal lifting of module corner with three corners fixed.
5 To original consumer purchaser. See full Limited Warranty for all conditions.